MainCatalogue of productsWIRES AND CORDS OF DIFFERENT SETTING, 739997

Search

 
News
01-02-2008
With 01.02.2008 new prices are entered on cable-explorer products. You look a price-list >>> ...
01-01-2006
With 01.01.2006 new prices are entered on cable-explorer products. You look a price-list >>> ...

739997
Wire with the twisted up copper tendons with PV isolation, with PV shell, flexible, on voltage 380V for the systems 380/660V
the same, but not intended for reinforcing an undemountable armature
CONSTRUCTION
1. CURRENT IS CONDUCTING WIRE copper or copper tin-plated (on call of user, at an order to the brand add the letter of ), round form, multiwire class 5 for 22483, by a section ot 0,75 to 6 mm².
2. ISOLATION from PVC plastic.
3. TWISTING the isolated tendons are twisted up without a filler. Isolated tendons it is assumed to twist up five-wires tendons round a mandrel.
4. SHELL from PVC plastic. Shell in wires is imposed with filling of intervals between tendons, giving wires round shape.
APPLICATION DOMAIN
For joining electro-devices and electro-instrument on the care of dwelling and his repair, washing-machines, refrigerators, facilities of small mechanization for gardening and truck farming and other similar machines and devices, and for making of cords extending on voltage 380V for the systems 380/660V.
TECHNICAL DESCRIPTION
Climatic execution for 15150:
    categories of placing 1, 2, 3
    T - categories of placing 4
    - categories of placing 4
Wires of execution At intended for exploitation at the temperature of environment . . . . . . . . . ot 40 to +40
Wires of the other executions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ot 25 to +40
Maximal temperature current-conducting tendon during exploitation . . . . . . . . . . . . . . . . . . . . . . . . . . +70
Wires after self-control in water at a temperature (205) during 1 ch
    must pass muster variable voltage 2000V frequencies 50 Hz. in a flow . . . . . . . . . . . . . . . . . . . . 15 min
Wires do not diffuse burning at a single gasket
Resource of wires, shown in firmness to sign to the variables
    deformations of bend at nominal voltage, no less . . . . . . . . . . . . . . . . . . . 30000 (60000) cycles (motions)
Set faultless work, no less . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5000 ch
Set faultless work for wires, applied in stationary electro-devices, no less . . . . . . . . . . . . . . . . . . . . 12000 ch
Build length of wires, no less . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 m
Guarantee term of exploitation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 from the day of putting into operation
    Term of service of wires, no less . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 years
    Term of service for wires, applied in stationary electro-devices, no less. . . . . . . . . . . . . . . . . . . . . 10 years

Number and nominal section of tendon, mm² Nominal thickness, mm Outward sizes for wires type of , mm Outward sizes for wires type of , mm Calculation mass 1 km of wire, kg
isolations shells min. max. min. max.
 
2 x 0,75 0,6 0,8 5,7 7,2 6,0 6,6 57,6
2 x 1,0 0,6 0,8 5,9 7,5 6,4 7,0 66,4
2 x 1,5 0,7 0,8 6,8 8,6 7,4 8,2 88,5
2 x 2,5 0,8 1,0 8,4 10,6 - - 134,0
3 x 0,75 0,6 0,8 6,0 7,6 6,4 7,0 68,2
3 x 1,0 0,6 0,8 6,3 8,0 6,8 7,6 77,8
3 x 1,5 0,7 0,9 7,4 9,4 8,0 8,8 110,9
3 x 2,5 0,8 1,1 9,2 11,4 - - 167,0
4 x 0,75 0,6 0,8 6,6 8,3 7,0 7,8 77,1
4 x 1,0 0,6 0,9 7,1 9,0 - - 93,8
4 x 1,5 0,7 1,0 8,4 10,5 - - 132,0
4 x 2,5 0,8 1,1 10,1 12,5 - - 205,0
5 x 0,75 0,6 0,9 7,4 9,3 - - 94,8
5 x 1,0 0,6 0,9 7,8 9,8 - - 111,0
5 x 1,5 0,7 1,1 9,3 11,6 - - 164,0
5 x 2,5 0,8 1,2 11,2 13,9 - - 253,0
 
N o t e: difference between any two values of outward diameter of wires, not intended for reinforcing an undemountable armature, on the same section (ovalness) must not exceed 15% maximal outward size; and the ovalness of wires, intended for reinforcing an undemountable armature, must not exceed 5% maximal outward size.