MainCatalogue of productsPOWER CABLES FOR STATIONARY GASKET, on 0,66 ; 1 V 16442 , on 0,66; 1 V 16442

Search

 
News
01-02-2008
With 01.02.2008 new prices are entered on cable-explorer products. You look a price-list >>> ...
01-01-2006
With 01.01.2006 new prices are entered on cable-explorer products. You look a price-list >>> ...

, on 0,66 V; 1 16442
Power cables with copper tendons, with PV isolation in PV shell with the protective covers of type and
, on 0,66; 1 V 16442
Power cables with copper tendons, with PV isolation in PV shell with the protective covers of type and with filling
CONSTRUCTION
1. CURRENT IS CONDUCTING WIRE copper, the same thingwire or multiwire, round or sector form, 1 or 2 classes for 22483.
2. ISOLATION from PVC plastic.
The isolated tendons of cables of multicores have the distinctive colouring. The isolation of zero tendons is executed blue color.
The isolation of tendons of grounding is executed two-color (green-yellow colouring).
3. TWISTING isolated tendons two-, three-, four- and five cables of tendons twisted up; two the cables of tendons have tendons of identical section; three-, four- and to five tendons have all tendons of identical section or one tendon of less section (tendon of grounding or zero).
4. FILLING cables type of and from PV plastic or not vulcanized rubber mixture.
5. SHELL from PV plastic.
6. PROTECTIVE COVER in cables type of type of :
    - pillow from a strong paper or ribbon of linen of unwoven glued and bitumen;
    - armour from two steel not zincked ribbons, imposed so that an overhead ribbon blocked gaps between the coils of lower ribbon;
    - outward cover from a bitumen, impregnated with cable yarn or flowed-yarn, bitumen, chalky composition.
In cables type of type of :
    pillow from a strong paper or ribbon of linen of unwoven glued and bitumen;
    armour from two steel ribbons, covered a bitumen and chalk.
APPLICATION DOMAIN
For a transmission and distributing of electric power in stationary options on nominal variable voltage 0,66 kV and 1 kV frequencies 50 Hz.
ables type of are used for a gasket in earth (trenches), if a cable is not exposed to considerable stretchings efforts.
ables type of are used for a gasket in apartments, in channels and tunnels, if a cable is not exposed to considerable stretchings efforts..
TECHNICAL DESCRIPTION
Type of climatic execution of cables of and T, categories of placing 1 and 5 for 15150-69
Range of temperatures of exploitation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ot 50 to +50
Relative humidity of air at a temperature to +35 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . to 98%
A gasket and editing of cables without the preliminary warming up is made at a temperature not below . . . 7
Minimum radius of bend at a gasket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.5 outward diameters
Nominal frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Hz.
Tester variable voltage frequency is 50 Hz.:
    on 0,66 V voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 V
    on 1 V voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3,5 V
Protractedly possible temperature of heating of tendons of cables during exploitation . . . . . . . . . . +70
Build length of cables for the sections of basic tendons:
    from 1,5 to 16 mm². . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450 m
    from 25 to 70 mm² . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300 m
    from 95 mm² and more. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 m
Guarantee term of exploitation . . . . . . . . . . . . . . . . . . . . 5 years from the date of input of cables in exploitation
Term of service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 years

Number and nominal section of tendon, mm² Outward diameter of cable, mm Mass of a 1 km. of cable, kg
0,66 V voltage 1 V voltage 0,66 V voltage 1 V voltage
 
Cables with round tendons
2 1,5 15,6 338
2 2,5 15,5 16,0 349 403
2 4 17,5 18,7 446 489
2 6 18,5 19,7 510 556
2 10 20,9 21,3 657 672
2 16 23,9 24,3 871 889
2 25 26,6 27,0 1143 1162
2 35 29,4 29,8 1568 1592
2 50 32,8 33,2 1958 1983
2 70* 36,2 2486
2 95* 40,4 3142
 
3 1,5 15,2 16,7 341 397
3 2,5 16,6 17,5 416 448
3 4 18,0 19,3 505 557
3 6 19,1 20,4 590 635
3 10 21,7 22,1 784 803
3 16 25,0 25,8 1070 1117
3 25 28,6 29,0 1618 1645
3 35 30,8 31,2 1969 1997
3 50 34,4 34,8 2492 2523
 
3 1,5 + 1 x 1,0 16,5 17,4 398 435
3 1,5 + 1 x 1,5 16,5 17,4 404 440
3 2,5 + 1 x 1,5 17,4 18,3 457 494
3 4 + 1 x 2,5 19,0 20,0 560 606
3 6 + 1 x 2,5 19,7 21,1 637 687
3 6 + 1 x 4 20,2 21,6 665 718
3 10 + 1 x 4 22,1 23,0 840 877
3 10 + 1 x 6 22,6 23,6 871 912
3 16 + 1 x 6 25,9 26,4 1173 1202
3 16 + 1 x 10 26,5 26,9 1232 1258
3 25 + 1 x 10 29,2 29,7 1747 1777
3 25 + 1 x 16 30,7 31,2 1863 1895
3 35 + 1 x 16 32,6 33,1 2224 2257
3 50 + 1 x 16 35,2 35,7 2692 2727
3 50 + 1 x 25 36,1 36,5 2815 2851
3 70 + 1 x 25* 39,0 3528
3 95 + 1 x 35* 44,1 4586
 
4 1,5 16,5 17,4 404 440
4 2,5 17,4 18,3 466 504
4 4 19,0 20,4 576 628
4 6 20,2 21,6 683 737
4 10 23,1 23,6 928 951
4 16 27,2 28,4 1316 1522
4 25 30,7 31,2 1954 1987
4 35 33,5 34,0 2439 2474
4 50 37,1 37,6 3068 3106
 
5 1,5 17,2 19,3 448 566
5 2,5 18,2 20,3 523 642
5 4 20,0 22,7 656 826
5 6 21,4 24,0 780 973
5 10 24,7 26,6 1090 1289
5 16 30,0 31,9 1748 2028
5 25 33,4 34,9 2354 2655
5 35 37,6 3263
 
Cables with the tendons of sectors
3 70 37,9 3277
3 95 41,4 4149
3 120 44,4 4989
3 150 47,4 5926
3 185 51,1 7091
3 240 56,6 8998
 
3 70 + 1 x 35 40,1 3686
3 95 + 1 x 50 44,4 4748
3 120 + 1 x 70 47,3 5760
3 150 + 1 x 70 50,4 6701
3 185 + 1 x 95 54,6 8173
3 240 + 1 x 120 60,0 10264
 
4 70 41,1 4058
4 95 45,4 5248
4 120 48,3 6296
4 150 51,6 7516
4 185 55,8 9079
4 240 61,4 11506
 
5 50 40,6 3806
5 70 45,0 4976
5 95 49,2 6384
5 120 52,8 7747
5 150 56,5 9400
5 185 60,3 11205
5 240 67,4 14035
 
Cables with round tendons
2 1,5 11,0 267
2 2,5 10,9 12,3 279 326
2 4 12,9 14,1 366 404
2 6 13,9 15,1 425 465
2 10 16,3 16,7 560 573
2 16 19,3 19,7 759 775
2 25 22,0 22,4 1018 1035
2 35 24,4 24,8 1428 1449
2 50 27,8 28,2 1801 1824
2 70* 31,2 2311
2 95* 35,4 2947
 
3 1,5 10,6 12,1 272 321
3 2,5 12,0 12,9 340 368
3 4 13,4 14,7 422 467
3 6 14,5 15,8 502 541
3 10 17,1 17,5 683 700
3 16 20,4 21,2 953 996
3 25 23,6 24,0 1482 1507
3 35 25,8 26,2 1822 1848
3 50 29,4 29,8 2327 2356
 
3 1,5 + 1 x 1,0 11,9 12,8 323 355
3 1,5 + 1 x 1,5 11,9 12,8 328 361
3 2,5 + 1 x 1,5 12,8 13,7 377 410
3 4 + 1 x 2,5 14,4 15,4 472 514
3 6 + 1 x 2,5 15,1 16,5 546 589
3 6 + 1 x 4 15,6 17,0 563 618
3 10 + 1 x 4 17,5 18,4 737 769
3 10 + 1 x 6 18,0 19,0 766 802
3 16 + 1 x 6 21,3 21,8 1051 1078
3 16 + 1 x 10 21,9 22,3 1108 1131
3 25 + 1 x 10 24,2 24,7 1608 1636
3 25 + 1 x 16 25,7 26,2 1616 1746
3 35 + 1 x 16 27,6 28,1 2068 2099
3 50 + 1 x 16 30,2 30,7 2523 2556
3 50 + 1 x 25 31,1 31,5 2641 2675
3 70 + 1 x 25* 34,0 3340
3 95 + 1 x 35* 39,1 4373
 
4 1,5 11,9 12,8 328 361
4 2,5 13,7 18,3 386 420
4 4 14,4 15,8 488 533
4 6 15,6 17,0 581 637
4 10 18,5 19,0 821 841
4 16 22,6 23,4 1188 1386
4 25 25,7 26,2 1807 1838
4 35 28,5 29,0 2278 2311
4 50 32,1 32,6 2889 2925
 
5 1,5 12,6 14,7 369 477
5 2,5 13,6 15,7 439 548
5 4 15,4 18,1 564 721
5 6 16,8 19,4 681 861
5 10 20,1 22,0 975 1164
5 16 25,0 26,9 1604 1675
5 25 28,4 29,9 2194 2487
5 35 32,6 3082
 
Cables with the tendons of sectors
3 70 32,9 3095
3 95 36,4 3949
3 120 39,4 4774
3 150 42,4 5697
3 185 46,1 6843
3 240 51,6 8723
 
3 70 + 1 x 35 35,1 3493
3 95 + 1 x 50 39,4 4534
3 120 + 1 x 70 42,3 5531
3 150 + 1 x 70 45,4 6457
3 185 + 1 x 95 49,6 7908
3 240 + 1 x 120 55,0 9272
 
4 70 36,1 3860
4 95 40,4 5029
4 120 43,3 6062
4 150 46,6 7266
4 185 50,8 8808
4 240 56,4 11208
 
5 50 35,9 3609
5 70 40,0 4758
5 95 44,2 6146
5 120 47,8 7491
5 150 51,5 9126
5 185 55,3 10912
5 240 62,4 13707
 
Cables with round tendons
2 1,5 11,6 12,4 287 317
2 2,5 12,3 13,7 329 384
2 4 14,3 15,5 430 484
2 6 15,3 16,5 502 550
2 10 18,1 18,5 696 717
2 16 21,1 21,5 957 982
2 25 25,0 25,4 1479 1511
2 35 27,4 27,8 1816 1850
2 50 30,8 31,2 2291 2328
 
3 1,5 12,0 13,5 311 366
3 2,5 13,4 14,3 385 420
3 4 14,8 16,1 479 537
3 6 15,9 17,2 569 621
3 10 18,9 19,3 803 826
3 16 22,6 24,2 1150 1375
3 25 26,2 26,6 1740 1774
3 35 28,8 29,2 2163 2200
3 50 32,4 32,8 2752 2793
 
3 1,5 + 1 x 1,0 13,3 14,2 365 403
3 1,5 + 1 x 1,5 13,3 14,2 368 406
3 2,5 + 1 x 1,5 14,2 15,1 425 466
3 4 + 1 x 2,5 15,8 16,8 536 570
3 6 + 1 x 2,5 16,9 18,3 625 692
3 6 + 1 x 4 17,4 18,8 656 728
3 10 + 1 x 4 19,3 20,2 843 893
3 10 + 1 x 6 19,8 20,8 883 942
3 16 + 1 x 6 24,3 24,8 1408 1438
3 16 + 1 x 10 24,9 25,3 1479 1512
3 25 + 1 x 10 27,2 27,7 1871 1906
3 25 + 1 x 16 28,7 2692 2039 2078
3 35 + 1 x 16 30,6 31,1 2404 2444
3 50 + 1 x 16 33,2 33,7 2901 2941
3 50 + 1 x 25 34,1 34,5 3057 3101
 
4 1,5 13,3 14,2 368 406
4 2,5 14,2 15,1 431 471
4 4 15,8 17,2 545 602
4 6 17,4 18,8 669 741
4 10 20,3 20,8 942 968
4 16 25,6 26,0 1572 1608
4 25 28,7 29,2 2104 2144
4 35 31,5 32,0 2625 2668
4 50 35,5 36,0 3363 3411
 
5 1,5 14,0 411
5 2,5 15,0 487
5 4 16,8 615
5 6 18,6 768
5 10 21,9 1103
5 16 27,6 1829
5 25 3149 2508
5 35 34,1 3103
5 50 38,6 4002
 
Cables with the tendons of sectors
 
4 70 39,9 4266
4 95 43,8 5432
4 120 47,1 6575
4 150 50,8 7867
4 185 55,8 10001
4 240 62,2 12698
 
* - produced on a technical decision.